NXP-BLF578XR

Symbol Parameter Conditions Min Typ/Nom Max Unit
frange frequency range 10 500 MHz
PL(1dB) nominal output power at 1 dB gain compression 1000 W
Test signal: Pulsed RF
PL output power VDS = 50 V; f = 225 MHz [0] 1400 W
Gp power gain VDS = 50 V; f = 225 MHz; IDq = 40 mA; PL = 1400 W [0] 22 23.5 dB
ηD drain efficiency VDS = 50 V; f = 225 MHz; IDq = 40 mA; PL = 1400 W [0] 65 69 %
RLin input return loss VDS = 50 V; IDq = 40 mA; PL = 1400 W [0] -17 -13 dB